カメラアクセサリー Alelion 1003220のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Alelion 1003220 16 ページ。 Lithium ion battery
Storage
Please note as all batteries the EasyPower battery has a certain self-discharge, this is mainly
due to power consumption of the inbuilt security system. Never store an EasyPower battery
that indicates or warns that the SOC is low, it should be charged at first given opportunity.
Store less than four (4) weeks; no special consideration needed, the battery should not risk
going to protect* due to self-discharge during this timeframe.
Store more than four (4) weeks; charge until full before the lift truck / EasyPower battery is
put in to storage. Follow this to avoid ending up in protect* mode due to the self-discharge
earlier then needed. Before it is put back in to use, charge again if needed.
*(See the subsection Troubleshooting/Protect Mode)
Control a stored EasyPower battery at least every sixth (6) month and charge if SOC <50%.
Driving
Always use lift truck according to the manufacturer's instructions. Normal operation should
not be any different for the operator until the EasyPower battery is almost empty. This will
be communicated to the lift truck and it will initiate various limitation actions. This can be as
an example; limited acceleration and/or lower lifting speed. When this occurs you are
driving on the last reserve and therefore should stop working and recharge your Easy Power
Battery.
For more specific information regarding the lift truck limitations when battery capacity
reaches the end, please refer to lift truck user manual.
Maintenance
Maintenance is only allowed to do be done by instructed personnel that have knowledge of
batteries with high energy content.
Once a week:
o
Control that the charging connections are undamaged.
o
Clean if needed, the EasyPower battery shall only be wiped off when cleaning.
Never use flowing water or high pressure cleaning.
Once a month:
o
Let the charger be connected to the EasyPower battery until it indicates battery
fully charged, at least once a month to keep it balanced*.
*(After a while with incomplete charging and loading cycles the need for balancing
might occur. This will ensure that all cells are fully charged and that you have all the
capacity at your disposal. The balancing is automatic and is done if needed with help of
the charger, at the end of the charging cycle.)
Remaining maintenance shall be done by service personnel at occasions that follows
ordinary service schedule for the lift truck.