• Keep other employees at a distance
For transport by vehicle, make sure the carton is stable prior to moving
3. SAFETY INFORMATION
3.1 WORKING ENVIRONMENT
PROCHONE is meant to be used with flammable and aggressive liquids, therefore you are
recommended to: - work in an environment which is compliant to sanitary and safety
regulations in force; make sure the room is adequately ventilated and free from ignition
sources.
Make sure you have easy access to fire-fighting devices close to PROCHONE and that such
devices are compliant to sanitary and safety regulations in force.
PROCHONE must be located so as not to be of hindrance to employees. Do not place
PROCHONE where employees move about.
Use under proper lighting. Avoid harsh environmental conditions.
3.2 PRELIMINARY CHECK
The system has been tested with flammable liquids (flammability point about 20 °C). Make
sure you have a safety data sheet for the liquid you use and you follow its instructions (ex.
Wear protective garments such as gloves and goggles, refrain from smoking, avoid polluting
the environment).
Special care must be taken during filling of the tank. Carry out the process cautiously until the
tank is full (MAX 3 l). In case of spill clean immediately.
Arrange connecting hose out of other employees' way.
Prior to starting the process verify that there is no leak either in the components or in the
connections to the system.
Plug the system only to 12 V DC supply line.
3.3 USE
Never leave PROCHONE unattended during functioning. Strictly follow the instructions here
below. PROCHONE must be used on a horizontal surface.
PROCHONE is meant to be used by a single reliable adult. All other people are recommended
to keep at a distance from the functioning appliance. Always wear protective garments (ex.
Gloves). Always request the safety data sheet of the products you use and follow its
instructions.