- ページ 13

体重計 Army Aviation TSS SeriesのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Army Aviation TSS Series 19 ページ。

1. In the condition of power on, hold on 【redisplay/calibration】
key for 3 second and enter in calibration mode to
display"CAL".
2. Confirm no load on the pan and press【M+/SMPL】key to
perform zero point calibration ,display "zero" on screen,
then display "value of weight to load".
3. If" value of weight to load" need be changed, respectively
press 【TARE】 key to move and press 【ZERO】 key to change
the value of weight to load.
4. Put required weight on the pan for 3-5 seconds and press
【M+/SMPL】key to display "SPAN", and display "PASS"
to return by it self in weighing mode.
5.7 UNIT SETTING (UNAPPROVED)
In general, the units need not reset because they were
already set before delivery. If setting need, the steps are
shown as the followings, units :kg, lb, oz, PCS, %, GSM,
g
Notice: The units kg and g are only allowed by rules to be
legal measure unit.
13