Troubleshooting

Item
Common Faults
Low or no output
1
flow (spray)
2
Spray not normal
3
Leaking
No power/
4
operation
Causes
Tank filter (end of
tube) is blocked
Nozzle (output) is
blocked
Pipeline is blocked
Low battery
(insu!cient power)
The nozzle is
damaged
Nozzle adjustment
improper setting
(output atomizing)
Diaphragm pump
issue
Tank is not securely in
place
Hose connection issue
Battery issue
The fuse is loose or
blown
Poor switch contact
Resolution
Clean the filter (pin)
Clean (removable) the
nozzle
Clean the pipeline
(disassembly may be
required, contact
service)
Charge or replace the
battery
Inspect nozzle for
potential replacement
Readjust (use tool)
Contact service for
diaphragm repair
Check seal and ensure
the lock is engaged to
secure the tank
Locate source of leak,
contact service if
problem persists
Charge or replace the
battery
Replace the fuse
(contact service)
Repair or replace
switch (contact
service)