- ページ 5

スイッチ CAMDEN SureWave CM-332 SeriesのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。CAMDEN SureWave CM-332 Series 8 ページ。 Active infrared "hands-free" switches

CAMDEN SureWave CM-332 Series 取付説明書
CM-331 & CM-332 Active Infrared "Hands-Free" Switches Installation Instructions
Momentary
When an object is in range of the sensor, Sure-Wave
operates momentarily. It will not operate again until the
object is removed and presented again. If the object
remains in range of the sensor, no alarms are generated.
Momentary with Alarm
When an object is in range of the sensor, Sure-Wave
operates momentarily. It will not operate again until the
object is removed and presented again. If the object
remains in range of the sensor for more than 30 seconds,
an audible and visual alarm is generated.
Maintained
When an object is in range of the sensor, Sure-Wave
activates and stays activated for as long as the object is in
range of the sensor. Once the object is removed, the Sure-
Wave deactivates.
Auto Range
The Auto Range Mode continually senses the environment
and adjusts Sure-Wave accordingly to eliminate false
triggers. Sure-Wave will calibrate itself with the first
stationary object detected. Objects in motion behind the
stationary object are not detected, but objects in motion in
front of the stationary object are detected by Sure-Wave.
If another stationary object is place in front of the original
stationary object, Sure-Wave re-calibrates itself against
the new stationary object. Objects in motion between the
old stationary object and the new stationary object are not
detected while objects in motion between Sure-Wave and
the new stationary object are detected.
Section 4: System Inspection
Instructions
After the Installation and operational check of the system:
1. Place warning label on the door (as per ANSI A156.10
or A156.19 guidelines). This will advise the person
entering the swing side zone that the door will move.
2. Instruct the owner on door system operation and how
to test it. This should be checked on a daily basis.
3. Instruct the owner on what to do if the door or any of
its components become damaged.
4. Strongly recommend to the owner that the complete
entry be inspected twice a year as part of the service
agreement.

Section 5: Technical Data

No. of IR Sensors
(2)
Operating Voltage 12-24 Volts, AC/DC ± 10%
Current Draw
40 mA
Standard
1"- 28" (25.4mm - 711.2mm)
Operating Range
6"-40" (152.4mm – 1.016m) Hand
Auto Range
6"-72" (152.4mm – 1.820m) Body
Operation
Relay Contact
3 Amps @ 30 V DC
Rating
Active Output
9-12V
Fail Safe or Fail-Secure
Output Type
- 'Request To Exit'
Inputs
- External (Door Contact) Input
Optional LED Ring On/Off, Red, Blue, Green
Current Draw
8Ma Max.
Tx-99 Plug-in 915mhz. Spread Spectrum
Wireless Output
Wireless Transmitter
Operating Modes
CM-331
Motion Sensing
- Momentary
Modes
- Momentary with Alarm
- Maintained (Latching)
Relay Operation
- Single Event
Modes
- Toggle
Relay Output
(1) Form 'C' (SPDT)

Section 6: Warranty

Camden Door Controls guarantees Sure-Wave™ to be free
from manufacturing defects for 3 years from date of sale.
If during the first 3 years the CM-331 & CM-332 fail to
perform correctly, it may be returned to our factory where
it will be repaired or replaced (at our discretion) without
charge. Except as stated herein, Camden extends no
warranties expressed or implied regarding function,
performance or service.
Page 5 of 8
CM-332
- Momentary
- Momentary with Alarm
- Maintained (Latching)
- Single Event
- Toggle
- Sequence
- Security
- Auto Range
(2) Form 'C' (SPDT)