Safety devices
C1 = Contact (N.C.) for reopening during closing.
Input for safety devices such as photocells, sensitive edges
and other devices compliant with the EN 12978 standard.
While the operator is closing, the opening of the contact
causes the reversal of the direction of movement until
completely open.
If C1 is not used, set dip switch 7 to ON.
CX with dip switch 8 and dip switch 9 OFF = Contact (N.C.)
for reclosing during opening.
Input for safety devices such as photocells, sensitive edges
and other devices compliant with the EN 12978 standard.
While the operator is opening, the closing of the contact
causes the reversal of the direction of movement until
completely closed.
CX with dip switch 8 OFF and dip switch 9 ON = Contact
(N.C.) for partial stop.
Input for safety devices such as photocells, sensitive edges
and other devices compliant with the EN 12978 standard.
Stops the operator, if it is moving, and then sets automatic
closing.
If CX is not used, set dip switch 8 to ON.
Photocell safety connection
With each opening or closing command, the panel checks that the photocells work. Any
anomaly inhibits any command.
Set dip switch 13 to ON.
DELTA
RX
DIR / DELTA-S
RX
DIR / DELTA S
Photocells
TX
Photocells
TX
DELTA