- ページ 10

電源 Diverse GENIUS-IIのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Diverse GENIUS-II 20 ページ。 Genius-ii power supply

Diverse GENIUS-II オーナーズマニュアル
to the caravan battery connections on the Genius-II. Use whichever connection
point is most convenient from a wiring perspective.
Note: A solar panel voltage regulator with maximum output voltage not exceeding
14.8 volts must be used at all times. Failure to use a voltage regulator may result
in power supply damage.

Remote Load-isolator Switch Connection

The Genius-II allows for remote control of the load connections. A pair of contacts
are provided for connection to the external switch. When this switch is closed, all
loads are disconnected from all power.
Battery charging is not effected by this switch.
The switch current when closed is less than 1 mA, so any convenient switch and
wire size may be used.
10