- ページ 13
電源 Diverse GENIUS-IIのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Diverse GENIUS-II 20 ページ。 Genius-ii power supply
This product is suitable for charging 12 V Sealed Lead-Acid (SLA) batteries
including Valve-Regulated Lead-Acid (VRLA) batteries, both Absorbed Glass Mat
(AGM) and Gel batteries.
Storage
If the caravan is to be stored for a long period of time, first fully charge the battery
and ensure all loads are disconnected. Recharge the battery at least once every
6 months. Regular recharging will prevent the battery from becoming deeply
discharged—a condition which can significantly shorten battery life.
Deeply Discharged Batteries
This battery charger is not designed to charge deeply discharged batteries. Its
effectiveness in charging such a battery is a function of the depth of discharge
and the battery size. Bigger (higher capacity) batteries will be more troublesome
in this respect.
In normal use a battery connected to the Genius-II should never become deeply
discharged, so recharging it should never be a problem.
If a battery has become deeply discharged and the Genius-II will not charge it,
remove the battery (see Battery Connection/Disconnection Procedure on
page 12) and charge it with a stand-alone charger. Once the battery voltage has
recovered to normal levels and the charge current is less than 15 A, it may be
reinstalled.
Servicing
This product contains hazardous voltages and energy hazards, which can result
in death or injury. Only properly qualified service personnel may service it.
There are no internal user serviceable parts. Only the fuses located in the
exposed terminal block area are user serviceable.
Isolate mains power, batteries and other DC input sources before servicing.
Fuses: Only the DC output Load and Battery fuses may be replaced.
Fuse ratings:
Factory-fitted
fuses:
Loads: 32 V Automotive Mini-blade Fuse, 15 A maximum
Battery: 32 V Automotive Regular Blade Fuse, 35 A maximum
Loads: 10 A
Battery: 30 A
13