- ページ 10

サーモスタット ESI ESRTP4RFのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。ESI ESRTP4RF 20 ページ。 Rf programmable room thermostat
ESI ESRTP4RF にも: ユーザーマニュアル (20 ページ)

ESI ESRTP4RF 取付説明書
date which is automatically set together with the
actual room temperature.

Fitting the Receiver

2.7
Installation
1. Loosen the screws on the back-plate and remove from
the Unit.
2. Fix the back-plate, terminals at the top, either direct
onto a flat wall using wall plugs and screws or on a flush
mounting single conduit box. Route the wires through
the back of the wall plate and fit the wires to the wall-
plate in accordance with the relevant diagram and in
accordance with I.E.E. regulations.
3. Fit the Unit onto back-plate, and tighten the screws.
4. Ensure an appropriate fuse is fitted to the circuit before
reconnecting to the mains supply.

Commissioning/Configuring

2.8
1. If the receiver and thermostat have been supplied as
a kit, the units have already been paired in the factory
and no pairing is needed.
2. Power up the receiver and press M/A (Manual/Auto)
button
MANUAL (green) light
3. On the thermostat, switch the slider to OFF. Press and
hold the A, H and + buttons for 3 seconds until the
symbol flashes.
4. When the light on the receiver stops flashing the two
units are paired.
5. If unsuccessful, repeat steps 2-3. If still unable to pair,
leave the unit powered on for 5 minutes and repeat the
steps above.
10
for approximately 10 seconds until the
1
begins to flash.
2