BMA 360D Commands

16. MUTE

Adjust or query mute settings of the BMA 360D microphone, individual beam silencing status, individual speaker
channels or AEC reference input.
Command format: MUTE [channel] [group id] [value]
[channel] = 1 to 12
[group] V = SmartMix, S = Speaker, B = Beam (Silenced status), R = AEC Reference
[Value] 1 = Muted/Silenced, 0 = Unmuted
Query format: MUTE [channel] [group id]
Response format: MUTE [channel] [group id] [value]

17. NAME

Adjust or query the Device Name.
Command format: NAME [string]
[string] = Text up to 40 characters.
Query format: NAME
Response format: NAME [string]

18. RESET

Causes a soft resets of the BMA 360D and retains all settings.
Command format: RESET
Response format: RESET

19. SERIAL

Returns the serial number of the BMA 360D .
Query format: SERIAL
Response: [Serial Number]

20. VER

Return the firmware revision of the BMA 360D .
Query format: VER
Response format: VER [version number]