ClearOne BMA 360D 참조 매뉴얼 - 페이지 8

{카테고리_이름} ClearOne BMA 360D에 대한 참조 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ClearOne BMA 360D 8 페이지.
ClearOne BMA 360D에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (5 페이지), 사용자 설명서 (19 페이지)

BMA 360D Commands

16. MUTE

Adjust or query mute settings of the BMA 360D microphone, individual beam silencing status, individual speaker
channels or AEC reference input.
Command format: MUTE [channel] [group id] [value]
[channel] = 1 to 12
[group] V = SmartMix, S = Speaker, B = Beam (Silenced status), R = AEC Reference
[Value] 1 = Muted/Silenced, 0 = Unmuted
Query format: MUTE [channel] [group id]
Response format: MUTE [channel] [group id] [value]

17. NAME

Adjust or query the Device Name.
Command format: NAME [string]
[string] = Text up to 40 characters.
Query format: NAME
Response format: NAME [string]

18. RESET

Causes a soft resets of the BMA 360D and retains all settings.
Command format: RESET
Response format: RESET

19. SERIAL

Returns the serial number of the BMA 360D .
Query format: SERIAL
Response: [Serial Number]

20. VER

Return the firmware revision of the BMA 360D .
Query format: VER
Response format: VER [version number]
8
Back to Table of Contents
Reference Manual
DOC-0579-001v1.0
September 2023