- ページ 6

フライヤー Alto-Shaam Fry Tech ASF-75DSのPDF インストレーション&メンテナンスマニュアルをオンラインで閲覧またはダウンロードできます。Alto-Shaam Fry Tech ASF-75DS 18 ページ。 Fryer dump station
Alto-Shaam Fry Tech ASF-75DS にも: 仕様 (2 ページ)

1.
It is the responsibility of the installer to verify
that this dump station installation is in
compliance with the specifications listed in this
manual and with local code requirements.
2.
Both holding and cleaning functions require
unobstructed access. The control panel must be
maintained free from obstruction.
3.
Locate the dump station on a firm, level surface
ONLY. The area surrounding the dump station
must be kept clear of all combustible materials.
4.
FOR YOUR SAFETY DO NOT store or use any
flammable liquids or allow flammable vapors in
the vicinity of this dump station or any other
appliance.
5.
FOR YOUR SAFETY DO NOT place
insulation or any other type of materials in
clearance areas.
6.
When properly installed, the dump station is
designed for operation adjacent to
non-combustible floors and walls with a 6"
clearance at the back. Clearances from all
combustible construction is a minimum of 6"
(152mm) at the back and both sides. Concrete,
tile, terrazzo, or metal surfaces are
recommended. Metal over a combustible
material may not meet code for non-combustible
surfaces. Verify site selection with local codes for
specific requirements.
Doit être utilisé seulement sur des planchers
non inflammables.
7.
Adequate means must be provided to limit the
movement of this appliance. A restraining device
is required for field installation.
8.
DO NOT install this dump station in any area
where it may be affected by any adverse
conditions such as steam or dripping water, etc.
DO NOT install the dump station over a drain.
F r y e r D u m p S t a t i o n O p e r a t i o n & C a r e M a n u a l • 5
I N S T A L L A T I O N
9.
LEVELING: Make certain
the fryer is positioned firmly
on all four supporting casters.
Level fryer front-to-back and
side-to-side by holding lower
collar (#2) while twisting
upper collar (#1). Restraining
ties can be used for
stabilization if necessary. Use
an allen wrench (#3) to lock
caster in position.
C
U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
Fire may be the result of improper
installation. Carefully read and follow
all installation instructions located in
this manual.
W A R N I N G

RISK OF ELECTRIC SHOCK.

Appliance must be secured
1
2
to building structure.
3