- ページ 4

ボイラー AKKAYA-BLOWTHERM SBK-YSB-HYBのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。AKKAYA-BLOWTHERM SBK-YSB-HYB 20 ページ。 Steam boilers

HYB MODEL - HYBRID TYPE BOILERS TECHNICAL SPECIFICATIONS
Type :
Water tube combustion chamber + 2 or 3 pass boiler
Furnace - Reverse Chamber: It is produced from the steel materials
Refrracter Materials:
It is used for supplying completely burning
in the furnace and reverse chamber
Materials :
Carbon steels as described in standards
Pipes :
Carbon steel tubes as indicated in standards.
Welding Quality:
It is done by certificated welder according to
EN 288 ,EN287-1
Fuel Type :
Solid - Liquid - Gas
3 pass back boiler specifications are same with SBK models
A front chamber made of water tubes are attached in order to get sufficient
combustion chamber volume and tuyer area
5
CAPACITY AND DIMENSIONS
Capacities for min. 5500 kcal/kg solid fuel and F&A 100 C (from and at 100 C)
6