GFCI MAINTENANCE:
Although the GFCI function works on its own, it is nec-
essary to test for proper function of your GFCI periodi-
cally.
To do this:
1.
Plug your equipment to an appropriate wall plug
2.
Press the "TEST" button on the GFCI panel
3.
Turn on the switches for "PUMP" and "MOTOR"
(located on the switch panel on the handle).
If your motors turn on, then the GFCI is NOT working
properly- do not use the equipment until this function
has been repaired. Take the machine to an authorized
repair location.
If neither motor powers on after pressing the "TEST"
button then the GFCI is working properly.
Press the "RESET" button on the GFCI and the CR2 will
be fully functional again.
WARNING: Do not remove the grounding pin
from your power cord. Doing so will prevent
the GFCI from performing properly and can
allow dangerous operating conditions to go un-
detected. Replace power cords without ground-
ing pins immediately.
RESET
BUTTON
TEST
BUTTON
GROUNDING INSTRUCTIONS:
This piece of equipment must be grounded. Should an
electrical malfunction occur, grounding provides a path
of least resistance for electrical current- reducing the risk
of electric shock. This piece of equipment is furnished
with a cord that has a grounding conductor and ground-
ing plug. The grounded plug must only be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordi-
nances.
WARNING:
Connecting the equipment to an improperly grounded
outlet can result in an increased risk of electric shock. A
qualified electrician should be consulted if you are unsure
that the outlet is properly grounded. Do not modify the
plug provided with the equipment. If it will not fit the
outlet, have a proper outlet installed by a qualified electri-
cian.
This appliance is designed for use on a 120-volt circuit.
The grounding plug provided looks like the plug illustrat-
ed in Figure 1. Replace the power cord if the grounding
pin is damaged or broken.
Extension cords connected to this machine should be
12 gauge, three-wire cords with three-prong plugs and
outlets. DO NOT use extension cords more than 25 feet
(7.6 m) long.
Figure 1