- ページ 8

DJ機材 djpower V-4のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。djpower V-4 17 ページ。 Super spark machine

Always connect the product to a grounded circuit. Before power on, make sure it is connected with
the rated voltage.
Turn on the machine, it will immediately start heating up.
5.2
On-device Control Panel
To access the control panel functions, use the four buttons located underneath the LCD display.
5.3
On-device Control Mode & Operation
5.3.1
Programming
Refer to the Menu Map to understand the menu options. The menu map shows the main level and a
variable number of programming levels for each option.
To go to the desired main level, press <MENU> repeatedly until the option shows on the display. This
will take you to the first programming level for that option.
To select an option or value within the current programming level, press "▲" or "▼" until the option
shows on the display. If there is another programming level, you will see that first option, or you will
see the selected value.
Press <MENU> repeatedly to switch menu pages.
Press <ENTER> to switch between current menu page and Standby Page at any time
5.3.2
Menu Map
Display
Heating Up
>>>>>>Temp. 200
Preparing
Page
Ready to Spark
Standby
>>>>>>Temp. 580
Page
Auto Heat-up
Manual
Mode
Pages
Button
<MENU>
<ENTER>
Description
The machine is heating up.
The machine could only start working when
reach the pre-set target temperature.
Finished heating up, ready to work.
Displays current heating system temperature.
Press <ENTER> to get back to this page at
any time (not DMX mode).
Press "▲" or "▼" to switch ON/OFF Auto
ON
Heat-up function.
The default setting of Auto Heat-up is ON. The Heat-up starts when the
machine is powered on. LCD will keep showing "Heating Up" until the
heating system reaches pre-set target temperature. When the LCD reads
"Ready to Spark", the machine is available for spark effect at the moment.
Function
Switch menu pages to select a function
Increases the numeric value of current function
Decreases the numeric value of current function
Switch between current menu page and Standby Page
- 7 -
Parameter
Range
550 -
630℃
ON/OFF