- ページ 6
パティオ・ヒーター Alva GHP50のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Alva GHP50 18 ページ。 Wall mounted patio heater
METHOD OF ASSEMBLY
Fig.A
purged (cleared out), before its first use. If it is not purged of air,
the heater will not work properly. This should happen at the gas
filling station when you fill up the cylinder. Always check this with
your gas supplier.
1. Before removing this heater from the packaging, read this
manual in full and make sure that it is what you want/need.
2. Remove the heater from the packaging.
9kg ALVA cylinder recommended
with a 5/8" BSP thread; horizontal
exit valve. The Bullnose Regulator
(not supplied with the heater)
tightens to the left hand side (anti-
clockwise) (figure A).
If you have bought a new gas
cylinder, the cylinder needs to be
HEATER SETUP
3
WARNING:
This heater oper-
ates directly on an
industrial cylinder with
a 5/8" HORIZONTAL
exit valve, (ALVA 9kg
industrial size). It is
NOT to be used on a
domestic cylinder with
a 3/8" VERTICAL exit
valve.