水ポンプ ASEPT nemco 06 10973のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。ASEPT nemco 06 10973 8 ページ。 Topping pump
Assembly
1
2
2-B
4
Internal Valve
OPTIONAL:
If dispensing a product with particulates such
as seeds, use internal valve to deliver more
consistent portions. The internal valve is not
needed when dispensing smooth products.
Insert internal valve between the neck of
pump and discharge valve.
Mount the discharge valve
onto the end of the pump housing.
Fit the pair of holes in the discharge valve
over the pegs on the neck of the pump
housing.
TIP: Lubricate parts with clean water to
ease fitting.
Insert the check valve
into the bottom of the pump housing.
Wrap the flaps on the side of valve onto the
pair of pegs on the pump housing.
TIP: Lubricate parts with clean water to
ease fitting.
for pouch Pump 10973
Mount the valve clip