- ページ 5
水ポンプ Acquaer AUP033-5のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Acquaer AUP033-5 13 ページ。 Automatic submersible utility pump
Note: Make certain you unwind the garden hose completely. Kinks in the hose will restrict the pump,
preventing it from priming, which is the first step to pumping water. The water level must be at
approximately 1-1/2 in. for the pump to prime and operate.
1. Plug the pump (A) into a 115 volt GFCI power outlet.
WARNING: Do not let plug fall in water and do not stand
in water while the pump (A) is plugged in.
Automatic Operation
The pump (A) will only turn on if there is approximately 1-1/2 in. of water around the pump. Water must
make contact with the sensor probes of the pump in order for it to turn on.
When the pump (A) removes water down to approximately 1/4 in., the pump will run for an additional 30
seconds and then turn off.
Note: If the pump (A) does not turn off, remove the pump and check to make sure that water or other
debris is not still contacting the sensor probes.
The pump can remain plugged in and will automatically turn back on when water reaches approximately
1-1/2 in. again.
Note: Do not disassemble the motor housing. This motor has NO repairable internal parts and
disassembling may cause an oil leak or dangerous electrical wiring issues.
Problem
1. Probes covered in debris
2. Blown fuse/tripped breaker
Pump does
3. Plug disconnected
not start or
4. Thermal overload
run
5. Corroded plug
6. Motor failed
1. Screen blocked
2. Hose kinked or coiled
3. Hose diameter too small
Pump cannot
4. Hose length too long
pump water
5. Impeller loose on shaft
out
6. Impeller broken
OPERATION INSTRUCTIONS
TROUBLESHOOTING
Possible Cause
1
On at 1-1/2 in.
On at 1/4 in.
1. Clean sensor probes
2. Replace fuse/reset breaker
3. Secure plug
4. Unplug the pump for 30 minutes, then
plug in
5. Clean plug prongs
6. Call 1-888-538-0082
1.Clean screen
2. Straighten hose
3. Use larger diameter hose
4. Use shorter hose
5. Reassemble impeller
6. Call 1-888-538-0082
5
A
Corrective Action