1. WHAT'S INCLUDED

1.1 Box #1 – SAM BOOST™ Electronic Components
A. Batteries & Battery Chargers
B. Wireless CAN Module & Antenna
C. Matrix Module
D. SAM BOOST™ System Harness
E. Cross Pump Backbone Harness with CAN Hubs
F. SAM BOOST™ Display, Display Labels, Power Module, & Adapter Plate
G. Alarm Buzzer (Optional)
H. Master Intake & Master Discharge Pressure Sensors
I. Caution Labels & Push-Pull Cover Placards
1.2 Box #2 – SAM BOOST™ Valves & Venting Components
a. 2" Preconnect Boost Valves, Pressure Sensors, & Valve Harnesses
b. Tank-to-Pump Boost Valve & Valve Harness
• Customer Specified, 3" or 4" Valve Size Available
c. Pump Venting Solenoid & Fittings
d. Water Tank Level Sensor & Fittings
e. Nozzle Color Handle Kit
2. PREPLAN INSTALLATION
□ Find optimal location for Antenna within 8' of Wire to Wireless CAN Module
□ Lay out all components included in kit on pump as shown in System Layout
□ Verify harnesses are within reach of components

3. VALVE INSTALLATION

□ Remove Original Valve Components (Controls, drains, etc.)
□ Install Boost Valves
• May require rotating electric actuators for clearance. If valve is rotated then
position sensor calibration (password 08266) must be performed
□ Install Pressure Sensor into Drain Line or Gauge Line near Valve
□ Connect Harnesses to Valve Electric Actuator
• Point Electrical Connection Ports down or sideways to avoid water intrusion
Sheet: FSG-MNL-00233
SAM BOOST™ WITH SMART NOZZLE N
Refer to FSG-MNL-00232 for complete listing of Safety Hazards & Warnings
Revision 7 / 10 / 2023