(10.1 WR-5 continued)
Programming of each WR-5 button is done from NE software when the WR-5 is wired to its host NE processor through the
remote data connector, and the processor is connected to a PC via Ethernet. Each WR-5 has its own identifying property and is thus
uniquely represented with its own software control surface, within which the button actions are programmed. Click the <Identify
Remote> button to find a physical WR-5. As mentioned, the Ashly RPS-18 power supply must be used to provide power for any
WR-5 units beyond four in series. Additionally, a provided jumper must be placed on the last and only the last WR-5 in a series, and
even if there is only one WR-5 used (see drawing).
10.2 RD-8C or RW-8C Remote Control (Remote Data)
A second microprocessor based desktop controller, the
Ashly RD-8C (or RW-8C wall mount), is an eight channel
level controller that uses slide faders for individual channel and
master level control and mute. The RD-8C is wired to the four
pin Data Input euroblock connector on the back panel. Only
one RD-8C can be wired to a NE processor. NOTE: When an
RD-8C is used, no other data port based remotes can be used.
In the software DSP control section, a remote gain func-
tion can be placed in any input or output and mapped to any of
the slide faders on an RD-8C for remote level control of that
channel. The RD-8C uses an XLR jack, while the RW-8C uses
a euroblock connector to wire to the NE processor (see wiring
diagram).
10.3 WR-1 Remote Level Control (5VDC)
Individual input or output channels can have remote level
control using a potentiometer assembly such as the Ashly WR-1
and four conductor wire. The WR-1 is a dual potentiometer
remote volume control designed to fit in a standard electrical
wall box. Each volume control is connected to a terminal block
on the WR-1 circuit board, which in turn must be wired to the
processor back panel euroblock connector labeled "5VDC
Remote Control" as shown. Do not connect the WR-1 remote
level control ground to any other external grounds.
12
Ashly RW-8C Remote Level Controller
Ashly WR-1 Remote DC Level Controller