Conversion instruction
Converting
For verification, you can find the values of the injector and simmer setting screws on the holder of
the injectors. The characters of the sets correspond with the characters on the label inside the lower
tray of the appliance (upper case characters for injectors and lower case characters for simmer
setting screws). The values are also indicated on the injectors and simmer setting screws. See table:
Gas
P
ULPG
2.75 kPa
The following sets can occur:
Set 'A-a' for simmer burner.
Set 'B-b' for semi rapid burner.
Set 'C-c' for rapid burner.
'H1-h', 'H2' and 'J-j' sets for wok burner.
NOTE!
It is possible that not all the injectors in the set will be used for the conversion of your appliance.
1. Replace the injectors in the burners.
Use a socket spanner (7) for disassembling/assembling the injectors in the burners.
2. Replace the simmer setting screws in the taps.
Use a screwdriver, flat-blade 4, for disassembling/assembling of the simmer setting screw and
when necessary use pliers.
3. On the wok burner, replace the injectors for outer (H1) and inner (H2) burner using an open end
spanner (7).
4
A
a
B
0.46
0.26
0.60
b
C
c
0.30
0.72
0.36
H1
H2
h
0.93
0.40
0.40
Plug
✔