- ページ 3

ヒーター Ambirad TORNADOのPDF 設置および操作マニュアルをオンラインで閲覧またはダウンロードできます。Ambirad TORNADO 16 ページ。 Gas fired mobile heater
Ambirad TORNADO にも: 取扱説明書 (8 ページ)

Installation Requirements.
2.1 Gas leaks
Propane gas is highly flammable and heavier than
air. Consequently in the event of a gas leak there
is a risk of explosion.
Prior to use, check gas supply connections with
leak detection solution. Never use a naked flame
when checking for a gas leak. In the event that
bubbles are noted either rectify if considered
competent or consult your supplier.
Do not use the heater until the fault is rectified.
In the event of a gas leak evacuate people from
the immediate area and open doors and windows.
Do not operate electrical switches.
If you suspect a large amount
escaped - call the Fire Service immediately.
After ventilating the room turn off the gas valve,
and disconnect the electrical connector to the
heater.
If the appliance is hot leave to cool then with the
aid of a competent person identify and rectify the
source of the leak.
2.2 Gas cylinders
This heater is designed to be used with at least
two 47kg propane bottles.

Technical details.

3.1 Dimensions
Gas cylinders are heavy, never attempt to lift a
cylinder, full or empty, by yourself. Always get
help.
Keep cylinders upright at all times during use,
transporting and when stored.
Liquid gas can cause severe freeze burns so
avoid skin contact by wearing gloves when
making connections or handling the cylinder. If ice
is noted on the cylinder ensure it is not leaking. If
leaking is suspected do not use the cylinder.
Do not drop or knock a gas cylinder as damaged
cylinders can be dangerous.
Do not store full or empty bottles in the operating
area of the heater and never apply heat to the
cylinder.
of gas has
2.3 Electrical supply
The heater is suitable for use with either a
230V/50Hz or 110V/50Hz supply. A selector
switch enables the user to choose the desired
voltage. See section 4.2.
Only female electrical connectors compatible to
the male connectors on the rear of the unit must
be used.
Always switch off and unplug the equipment when
not in use.
3.2 Technical Data
Heat input gas
Gas type
Gas category
Supply pressure
Nozzle pressure
Injector size
Electrical supply
Electrical input
Weight
Hose (Ambi-Rad
Part No 201308
Regulator
Min Room size
Req'd ventilation
*approved to EN 1763-1 BS3212 (UK Only)
kW
45
Propane G31
I3p(37)
I3p(30)
mbar
37
mbar
16.0
7x1.8
V
230/110
W
400
kg
85
1.2m lg, 10mm ID*
kg/h
4
mbar
37
m3
510
cm2
1275
30
4
30