AMCI 7551 빠른 시작 매뉴얼 - 페이지 3

{카테고리_이름} AMCI 7551에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AMCI 7551 11 페이지. Intelligent ldt interface module
AMCI 7551에 대해서도 마찬가지입니다: 수동 부록 (3 페이지)

AMCI 7551 빠른 시작 매뉴얼
Installation (cont'd)

Cable Installation

Cables can be ordered directly from the LDT manufacturer. Optionally, MTS specifies BELDEN #8105 for
use as an extention cable.
The following figures are wiring diagrams for Balluff and Temposonics II transducers. Follow the LDT
manufacturers' guidelines for maximum cable length and installation.
GRAY
8
GREEN
7
PINK
6
YELLOW
5
SHIELDS
4
WHITE
3
BLUE
2
BROWN
1
Module Connector
AMCI Part #: MS-8
Phoenix #:
MSTB1.5/8-ST-5.08
Module Connector
AMCI Part #: MS-8
Phoenix #:
MSTB1.5/8-ST-5.08
ORANGE/WHT
8
WHITE/ORN
7
GRAY/WHT
6
WHITE/GRY
5
SHIELDS
4
GREEN/WHT
3
WHITE/BLU
2
WHITE/GRN
1
+15V
GND
±15Vdc Power Supply
Plymouth Industrial Park, Terryville CT 06786
Tel: (203) 585-1254 Fax: (203) 584-1973
S
7500 I
ERIES
Overall Shield
+ STOP
- STOP
- INTERROGATE
+ INTERROGATE
SHIELDS
- 15 Vdc
+ 15 Vdc
SUPPLY GROUND
+15V
GND
-15V
±15Vdc Power Supply
AMCI and Balluff LDT Cable Drawing
Overall Shield
*
+ START/STOP
- START/STOP
- INTERROGATION
+ INTERROGATION
SHIELDS
- 15 Vdc
+ 15 Vdc
DC GROUND
BLUE/WHT
FRAME GND
BROWN/WHT
WHITE/BRN
-15V
Temposonics II LDT Cable Drawing
LDT I
NTELLIGENT
BELDEN CABLE #8105 or exact equ.
* Cable for Transducers with RPM Personality Module is shown.
For Transducers with DPM Personality Module, the following pins are renamed:
+ Start/Stop renamed to + Gate Out
- Start/Stop renamed to - Gate Out.
M
NTERFACE
ODULE
3