Mark Curb Centerline & Measure Segments
Pencil mark the curb centerline as shown. Measure the left, center
and right segment lengths and jot down their measurements in the
spaces provided below. These are critical dimensions, so make
sure to double-check your measurements.
M E A S
U R E
T O I
N T E R
S E C T
I O N
left segment length _____+ 1" = left Sill trim length
right segment length _____+ 1" = right Sill trim length
center segment length ____+ 9/16" = center Sill trim length
Trim Sill Pieces
Sill (A) and Header (B) pieces are identical in appearance except for
the weep holes on the Sill pieces (Sill pieces have weep holes;
Header pieces do not). Trim the Sill pieces to the lengths specified
in step 1.
Assemble and Position Sill on Curb
Assemble Sill (A) by inserting Corner Brackets (R) into Sill pieces
and bringing the pieces together (see figure above and exploded
view - sheet 3).
Using the Corner Bracket holes as guides, mark and drill the Sill
pieces with a 1/8" drill bit. Secure the Corner Brackets to the Sill
pieces with eight(8) #6 x 1/4" machine screws (S). Now run a bead
of caulking on inside of crevice where Sill pieces join to insure no
leaks. Position Sill on curb. Temporarily tape Sill to curb to prevent
movement.
E T
S U R
M E A
E C T
E R S
ME AS UR E
I N T
Position and Install Wall Jambs
O
I O N
Place Wall Jambs (D) into ends of Sill (A) and up against the shower
walls as shown. Plumb the Jambs, then pencil mark the installation
hole locations on the shower walls (3 per Jamb). Remove Wall
jambs. Using a 3/16 masonry bit, drill 1-1/4" deep installation holes
in locations previously marked. Insert Plastic Screw Anchors (P)
into holes. Reposition Jambs as before and secure to wall using
six(6) 8112P Installation Screws (O)
Install Glass Panels
Insert glass support Setting Blocks (Q) into the Sill cavity as shown.
Set the Glass Panels (U) on the Setting Blocks and slide Glass
Panels a 1/2" into its respective Wall Jamb (D). Hold panels in place
by inserting a short piece of Glazing Vinyl (V) between Glass Panels
and the Wall Jambs, both inside and out.
Install 45 degree Corner Posts
Glass Panels must have a 1/2" insertion into their Wall Jamb and the
45 degree Corner Post in order for glazing vinyl to hold glass
properly.
Slide 45 degree Corner Posts (E) over the exposed edge of the
Glass Panels and set them into Sill cavity as shown. Double check
for 1/2" insertion before proceeding.
( 4 )
4