All electrical wiring must be installed in accordance with the National Electrical Code and with all
local codes. All wiring shall be done by a qualified electrician. Run one, two or three branch circuits
(as required) from the main electrical service panel to the pump area of the framing structure to
provide power to the unit.
Electrical components have specific wiring requirements. Refer to the matrix below for the electrical
supply requirements for the whirlpool bathtub and factory installed components.
Branch circuits must be rated for 110 – 120 volts. Use 12 Gauge, 3 conductor cable for the circuits.
If the length run exceeds 100 feet, check with local codes for requirements. Install moisture proof
junction box(s) 6" above the floor at the pump end of the framing for each circuit.
DO NOT INSTALL THE JUNCTION BOX(S) WHERE IT CAN BE REACHED WHILE SITTING OR
STANDING IN THE TUB OR TOUCHING THE FAUCETS.
WHIRLPOOL & AIR SPA CONFIGURATIONS FOR FACTORY INSTALLED COMPONENTS
This section lists the factory installed components of the Whirlpool and/or Air Spa Systems.
Note the required number of circuits and their rating for the Whirlpool & Air Spa unit you are planning to install.
CONFIGURATION LABEL FOR FACTORY INSTALLED COMPONENTS
Soaker w / Quick Drain™
Soaker w / Light
Soaker w / Quick Drain™ w / Light
Whirlpool or Air Spa
Whirlpool or Air Spa w / Light
Whirlpool or Air Spa w/ Quick Drain™
Whirlpool or Air Spa w/ Light & Quick Drain™
Whirlpool & Air Spa (Combo)
Whirlpool & Air Spa (Combo) w/ Light
Whirlpool & Air Spa (Combo) w/ Quick Drain™
Whirlpool & Air Spa (Combo) w/ Light & Quick Drain™
IN-LINE HEATERS REQUIRE ITS OWN 15 AMP GFCI DEDICATED CIRCUIT
All electrical connections must be carried out by a certified electrician in accordance with local electrical
requirements and codes.
ELECTRICAL INSTALLATION
Systems
Electrical Rating Circuit 1
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
20 Amp GFCI
20 Amp GFCI
7
OWNERS MANUAL
Electrical Rating Circuit 2
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI
15 Amp GFCI