Roughing-in Dimensions
GENERAL DESCRIPTION:
Electronic faucet with proximity operation. Vandal
resistant solid brass construction single post
mounting. Operates on DC (battery) or AC
permanent power. In-line strainer for solenoid is
integral. Single inlet 3/8 compression, built-in
checks, and flexible stainless steel 16-1/4" reach
inlet hose for spout connection.
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
RECOMMENDED TOOLS
1 Channel Locks
2 Adjustable Wrench
3 Plumbers' Putty or Caulking
4 Phillips Screwdriver
INSTALLATION
INSTALL SPOUT ASSEMBLY;
1
Fig. 1
Turn off hot and cold water
CAUTION
supplies before beginning
1. Connect the two 27" EXTENSION CABLES (1) to
the Faucet Sensor Cables. Fig. 1.
2. Insert 27" EXTENSION CABLES (1), FLEX HOSE
(2) and SPOUT SHANK (3) through center hole of
mounting surface. Fig. 1.
3. Assemble "C" WASHER (4), STAR WASHER (5)
and LOCKNUT (6) onto threads of SPOUT SHANK (3)
from underside of mounting surface. Fig. 1a.
4. Align FAUCET and tighten LOCKNUT (6). Fig. 1a.
Note: 4" and 8" Deck Plates are available for other
installations, see page one for information.
2-1/8" DIA.
32mm
(1-1/4) DIA.
413mm
(16-1/4)
5 Flat Blade Screwdriver
6 Electric Drill & 1/4"
Drill Bit
7 Tape Measure
(127mm)
5"
(53mm)
60mm
(2-3/8) MAX.
81mm
(3-3/16)
3/8" COMP.
1
3
Fig. 1
2
Fig. 1a
2
(243mm)
9-9/16"
(133mm)
5-1/4"
MOUNTING
SURFACE
114mm
(4-1/2)
500mm
(20")
7
4
10'
5
SENSOR
CABLES
3
1
1
3
6
5
4
125mm
(4-7/8)
1524mm
(60)
2
6
M 9 6 5 119 R E V. 1. 3