7. TROUBLESHOOTING
OVERLOAD PROTECTION:
The pump has a thermal overload safety device. In the event of any overhea- ting of the motor, this device automatically
switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatically comes on again.
If the overload cutout is tripped, it is essential to identify and deal with the cause of the overheating.
See Troubleshooting.
Fault
The pump does not run.
Suction filter clogged.
Suction filter clogged.
DAB PUMPS reserves the right to make modifications without notice
Possible causes
Power cord unplugged.
Impeller jammed.
Water level under the suction
minimum.
Air bubble in the pump, produced
during the plunge.
Suction filter clogged.
Discharge tube clogged or obstructed.
The thermal overload protection in the
pump has activated.
Water Temperature exceeds 95°F.
The pump ran dry
Solutions
Plug cord securely into the socket and
check if there is voltage on the line.
Disconnect the power cord, disassemble
hydraulic part and check if impeller is free
to run.
Stop the pump. Reposition pump to ensure
pump is always fully submerged.
Get the air out by plunging again the pump
while in a tilted position and shake it with
the discharge tube open
Disconnect the power cord, clean the
hydraulic part.
Disconnect the power cord:
take off the tube and clean it.
Clean water intake area. Allow pump to
cool for approximately 30 minutes.
Maximum water temperature must not
exceed 95°F.
Reposition pump to ensure pump is
always fully submerged.