{카테고리_이름} Door Knox VDP301에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Door Knox VDP301 13 페이지. Wireless external door entry kit

Door Knox VDP301 사용자 설명서
2. Wiring diagrams for magnetic lock and electric lock connections are shown below.
Connect electric lock to terminals 4 and 6 or connect a magnetic lock to terminals 5 and 6.
Note: When the camera is only powered by a lithium battery without any extra power supply,
the camera unit electric lock cannot be released.
Electric Lock

Magnetic Lock

Terminal
1
12v DC
2
0v
3
Door Release. Link to 0v to operate relay
4
Relay N.O (Normally Open)
5
Relay N.C (Normally Closed)
6
Relay Common
4. Install the weather shield at 1.5m-1.8m above ground level avoiding direct sunlight.
Email:
Function
Doc XVDP400
NOTE: Relay Contacts 3A 30v DC