DoorHan CV01 소유자 매뉴얼 - 페이지 7

{카테고리_이름} DoorHan CV01에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DoorHan CV01 12 페이지.
DoorHan CV01에 대해서도 마찬가지입니다: 설치 및 운영 매뉴얼 (4 페이지), 매뉴얼 (8 페이지)

DoorHan CV01 소유자 매뉴얼

1. GENERAL INFORMATION

CV01 control unit is designed for remote and stationary control of:
ƒ electrical locks;
ƒ sectional door operators;
ƒ electric drives for sunshades, window shutters and rolling doors;
ƒ lighting.
It can also be used to provide effective operation of other companies' drives with DoorHan remote controls and to automate
various devices.

2. SPECIFICATIONS

Parameters
Supply voltage
Maximum rated current, not more than
Maximum rated voltage
Fuse breaking capacity
Number of operated drives
Operating temperature
Electrical protection class according to GOST 27570
IP code (waterproof and dustproof ratings)
Type of control
Remote control, key-switch
Press the "Open" button
Press the "Close" button
Press and hold the "Open" button
for more than 5 sec
Press and hold the "Close" but-
ton for more than 5 sec
Multi-channel remote control
Press the "Open" button
Press the "Close" button
Press the "Stop" button

3. INSTALLATION

1. Remove the control unit from the packaging. Unscrew the four screws located on the device casing, and take off the cover.
2. Carefully unscrew the two mounting screws on the control board and remove it from the casing.
3. Make the electrical connections in accordance with fig. 1, 2, 3.
4. Carefully attach the control board into the casing using the two mounting screws and close the cover.
5. Ensure maximum protection of the device from dust and moisture during installation. Use cable entries to connect mounting
wires to the control board.
WARNING!
ƒ Ensure minimum distance of 50 cm between the device and the ground level.
ƒ Minimum distance between neighbouring control units should be 20 cm at least.
ƒ Take the receiver antenna out of the casing to ensure proper signal reception.
open
starts to close
starts to close
starts to close
starts to close
starts to close
Table 1. Control unit technical characteristics
Table 2. State of the rolling shutter when operated with control unit
State of the rolling shutter
closed
starts to open
starts to open
opens till the button is
starts to open
starts to open
GENERAL INFORMATION
Value
220 V, 50–60 Hz
4 A
220 V ± 10 %
4 A
1
-40...+70 °C
II
IP 54
is opening
stops
stops
released
closes till the button is
starts to close
starts to close
stops
is closing
stops
stops
starts to open
released
starts to open
stops
7