6. PROGRAMMING

6.1. DIP SWITCHES
DIP switches are used to switch between the operating modes of the control unit board.
WARNING!
 Prior to switching between the operating modes turn the power supply OFF.
 When using the device for the first time make sure the DIP switches 1 and 2 are in correct position.
Table 6.1.1. DIP switches operation
DCUН-2 operating mode
DIP 1 = Off
DIP 2 = Off
DIP 3 is used to enter the advanced menu.
DIP 3 = Off (main menu)
DIP 3 = On (advanced menu)
DIP 4 is not used
Menu screen shows dH2
In DCUH-2 mode each operation of the door and dock leveler is displayed on the menu screen accordingly (see Ta-
ble 6.1.2).
8
Shaft operator control board terminals
OPEN
STOP
red
Lip inductive
Shaft operator
position sensor
control post
DCUН-3 operating mode
DIP 1 = Off
DIP 2 = On
DIP 3 is used to enter the advanced menu.
DIP 3 = Off (main menu)
DIP 3 = On (advanced menu)
DIP 4 is not used
Menu screen shows dH3
CLOSE
black
blue