7) [Optional ] Mount the lighting:
Leds Halospot.
Circular Leds.
8) Mount the nozzle on the water outlet. Use de pipe or thread in function of the
project to install.
The assembly of the pipe is necessary to place the nozzle out of the waterjet,
and stabilize the flow before the nozzle.
2.2
WIRING AND PIPING
2.2.1
Hydraulic
Connect the rigid pipe and the stainless steel or plastic thread nozzle to the
impulsion of the pump (③) (1-1/2" RH).
WARNING: Risk of unit damage. Clean all piping prior to connecting and starting the
unit up.
WARNING: Risk of unit damage. Install a 130 µm filter before water inlet.
2.2.2
Electric
Connect the main power supply of the equipment to 230V AC using
protections with a 30mA differential circuit breaker, a magnetothermal circuit
breaker and earth connection.
Connect the DMX wire to the equipment. Use a waterproof DMX wire.
WARNING: Risk of unit damage. Check that all IP68 connectors are properly sealed
and they prevent water getting through. Electrical components may become
damaged by flooding, causing the unit warranty loss.
3
OPERATION AND MAINTENANCE
The range of DMX channels with which the pump works goes from 0 to 255,
having the value 10 as a minimum height of the pump jet, and 255 as the maximum
height.