PROBE:
Place the pH probe on the salt chlorinator chamber in the space provided.
Important: ensure that the probe is placed so that the two protective edges of the glass ball are
perpendicular to the flow.
Earth
Flow switch
Arrow in the
direction of
flow
FLOW SWITCH:
We advise the installation of the flow switch in the following cases
-
Filtration pump situated above the water level (risk of un-priming).
-
Chamber installed in a bypass configuration.
Installation: Install the flow switch in the place on the chamber designed for the purpose and
position the arrow above it in the direction of the water flow.
Operating principle: If the flow is interrupted accidentally or during a backwash and whenever the
water flow-rate is less than 2.9 m
Warning:
-
The flow switch provided contains its own system of recognition. If you need to replace it,
contact your specialised dealer.
-
If the flow switch is not plugged in, the device will work normally, regardless of the presence
of hydraulic flow. It is, therefore, absolutely necessary for the unit to be controlled by the
filtration pump in order to ensure that water is circulating when chlorine is being produced
and pH correctors injected.
FLOW
pH PROBE
Salt electrode
3
/h, the flow switch will cut chlorine production.