Important Safety & Electrical Information
Important Safety & Electrical Information
THIS CLASS II APPLIANCE DOES NOT REQUIRE AN EARTH
CAUTION: 230V AC
Lethal Voltage present on the AC supply
Ensure mains power supply is switched OFF before starting wiring
DO NOT take risks with plumbing or electrical installation. This product
must be installed and serviced by a competent person in accordance with
the current edition of the Wiring Regulations (BS7671), local by-laws and
the current building regulations.
This product must be installed, used and maintained in good working
order in accordance with these instructions and recommendations.
If the supply cord is damaged, it MUST be replaced in order to avoid
hazard.
The 230V AC power supply to this unit must be provided via a two-pole isolator switch and a
dedicated circuit with a 30mA RCD device installed in accordance with the latest revision of
the Wiring Regulations BS7671. It must be wired into a fused, unswitched, fixed wiring
connector fitted with a 5 amp fuse.
The IP45 rating of the AKW pump product refers to the inner casing containing the electrical
control gear. The pump motor which operates at SELV is located within the outer cover.
Product Specifications
Product Specifications
AKW M17 DigiPump high performance shower waste water pump.
Pump Specification
SUPPLY: 230V AC 50Hz 100W
IP45
DUTY CYCLE: 50% max 30 mins on.
Quiet in operation.
For use with electric & mixer showers.
Pump and controller enclosed in one unit.
Max flow rate: 17 Litres Per Minute (LPM).
,
Non-handed
selectable inlet/outlet direction.
Note: Increased Head/Lift conditions will
affect the pump's performance.
:
Pump Capacity:
17 LPM MAX under head/lift
conditions.
Derate accordingly for installed
conditions.
Max Head: 1.0m (39in).
Max Lift: 0.5m (20in).
MAX COMBINED HEAD + LIFT:
1.5m (59in).
4