The pump unit must be located on a vertical surface with the waste water inlet/outlet connections horizontal
at the bottom of the unit.
The unit must be located away from the direct line of water jets.
Cable to and from the pump must be run directly out of zone 1 by the shortest route into the vertical surface.
Cables must be protected against mechanical damage and sealed against water ingress.
The clearance behind the unit and separation from the wall must be minimal and the gap must not be sealed.
no cable joints may be made in zone 1.
The outer cover must be correctly fitted.
Electric Shower
Mains Supply
Consumer unit
30ma RCD
5a double-pole
un-switched fused
spur
Controller and Pump
Mixer Shower
Mains Supply
Consumer unit
30ma RCD
5a double-pole
un-switched fused
spur
Controller and Pump
Order: 01905 823 299
|
orders.akw-ltd.co.uk
Isolating valve
filter
Isolating valves
Sensor cables

electrical Installation

electric Shower
Mixer Shower
Technical Support: 01905 560 219
flow Switch option - Showers
without pump control output
Wired connection option -
Showers with pump control
output
Wireless Pump Interface option -
compatible aKW showers only
filter
flow Switches
11