Pre-Heater Installation

Step 1: Create Cavity Below Thermostat
• The purpose of the cavity is to allow the connection joint (the rubbery
insulation covered junction between the element and cold tail) to be
recessed into the floor
• Using a chisel and hammer or angle grinder, chip away some of the sub
floor with a chisel to form a 10mm deep cavity
• The width of the cavity will depend on the number of heaters to be
connected to the thermostat
Step 2: Place Cold Tail
• Connect (e.g. using tape) the cold tail to the draw wire and pull it up through the pre-installed conduit
or wall cavity to the thermostat position
• Secure (using either hot glue or tape) the connector joint(s) into the cavity created below the
thermostat position
Step 3: Connect Monitor
• The purpose of the monitor is to confirm that the heater is working and not been compromised.
• The monitor should remain connected until the floor has been installed and your electrician connects
the thermostat.
• Test the monitor before connecting to heater: Switching the monitor on with no heater connection
should sound the alarm and turn on the red light. If these things don't occur, check that the battery is
connected properly or replace the battery.
• Ensure the heaters to be monitored are not connected to a power source
• Connect the various wires to the alligator clips and pull the rubber boots over the metal clips:
o Green alligator clip – green wire
o Red alligator clip – brown wire
o Black alligator clip – blue wire
o Recommendation: Each clip can be taped up with insulation tape to prevent the clips from
touching and setting off the alarm
• Once connected, there should be a white light which indicates that the monitor is checking the heater
for damage.
• Hang or place the monitor where it can be seen and heard during the installation
• Should the white light go out, batteries will need to be replaced
• The alarm sounding and a red light indicates that, either:
o A lead wire has come loose from the terminals;
o The red or black alligator clip is touching the green alligator clip; or
o Damage has occurred to the heater.
• It is important to stop work and identify the cause of the alarm sounding immediately.
• In the event of damage to the heater, call Coldbuster on 1800 85 75 65 for assistance.