1 Introduction

1.1 Purpose

This document presents the procedure to apply in order to replace a SSD Flash in a
DCP-2000 or a DCP-2K4 unit.
The document is presented as a step-by-step procedure that must be followed as
specific steps might require that previous steps were completed.
CAUTION:
The procedure presented in this document must ONLY be
performed by a qualified technician, that is properly grounded in
accordance to the ESD rules presented in ISO 9001 (2000).

1.2 Procedure Applicability

The procedure presented in this document ONLY applies to DCP-2000/DCP-2K4 units
fitted with the motherboard X7SBE (SuperMicro) - this motherboard usage is flagged
using a "D" at the end of the unit's serial number on the rear side of the unit (e.g S/N:
201235D).
D2K.DP.000804.DRM
Page 3
Doremi Cinema LLC Confidential
Version 1.0