changed. Go back to the SETUP Mode and make a change.
If the above described failure occurs - or any other unit failures
occur - a Rexcon service representative should be contacted. There
are no user serviceable parts inside the Die Sentry Units.
APPENDIX C - TROUBLESHOOTING
PROBLEM: NUISANCE STOPS
CAUSE: REMEDY:
1. Pinched or Broken probe wire. Check and Repair if necessary.
2. Inconsistent Feed Time. Check solenoid valves, air pressure, etc.
on feeder.
3. Press Speed (Cycles per Minute). Increase Speed of press is
slower than the probe TIME or Reset TIME of probe examine
window.
CAM SETUP.
4. False Sensing of probe during cycle. Check to see NO other
obstacle comes in contact with the probe.
Check probe light on unit to see if it comes on anytime other than
when part is in place.
5. Loss of Examine Light on unit for Check CAM switch contact
closure for the a probe. probe.
Check examine time for the probe.
PROBLEM: PRESS DID NOT STOP WHEN IT SHOULD HAVE
CAUSE: REMEDY:
1. False Sensing on probe before or during Check probe so it does
not hit top of die during examine period cycle.
Check Scrap metal so it does not flip up to touch probe.
Check probe so that it only senses material at the very end of feed
length.
2. Press speed faster than when probe times Readjust examine
setting with CAM and/or were set. TIME.
3. Examine light stays on too long . Decrease length of CAM (CAM