Response time, (time constant) T50
Sensor
Sensor
Liquid
diameter
tip
0,4 m/sec
Ø6 mm
Fast
<1,5 sec
Standard
<6,1 sec
8 mm
Fast
<1,5 sec
Standard
<7,6 sec
1
100 %
2
80 %
1: Sensor without thermowell
3
(Embedded sensor)
60 %
2: Sensor with thermowell,
40 %
with thermal compound
20 %
3: Sensor with thermowell,
without thermal compound
0%
0
1
2
3
4
5
6
Electrical connection Pt100
To connect with Pt100 output with ceramic terminal block
1 × Pt100
Electrical connection 4 ... 20 mA
®
FlexTop
22xx
2-w
Electrical connection DFON display
CombiView DFON display
www.baumer.com
Air
Air
3 m/sec
0 m/sec
<21,4 sec <135,6 sec
<27,2 sec <137,8 sec
<33,6 sec <181,0 sec
<47,7 sec <200,9 sec
Note:
When a thermowell
is used, the time
delay increases.
The delay is the
time duration for
the sensor to reflect
the correct temper-
ature after a tem-
perature change in
the media.
7
8
9
10 Minutes
2 × Pt100
To connect the
To connect the
®
FlexTop
22xx
FlexProgrammer 9701
Pt100
4-w 3-w
2-w
– Com 2
(black)
– 4...20 mA
+
Connection with 4 ... 20 mA loop
+
– (4...20 mA)
Relay 2
Com 1
(red)
Connection for
FlexProgrammer 9701
Operating Instructions: 11163172 06 EN
Temperature sensor
CombiTemp TFRN/TFRH
Operating instructions
Process temperature
°C 400
Process
temperature
350
300
250
200
150
100
To connect Pt100 output with M12 connector
1 × Pt100
1 2-wire Pt100
2 3-wire Pt100
Pt100
3 2-wire Pt100
4 4-wire Pt100
5 N.C
Com 1 +
(red)
Electrical connection with cable gland
Cable diameter M16 plastic
M16 stainless steel
M20 plastic
Relay 1
M20 stainless steel
Check the maximum temperature for the cable used
Be sure to fixate the instrument before tightening the cable gland.
When using M16 stainless steel and M20 stainless steel the
Com 2
maximum tightening torque is 4 Nm.
(black)
When upgrading the TFRx without display with a DFON touch
screen, remember to remove the O-ring from the sealing. Otherwise
the sealing won't be tight.
50
0
20
40
60
With cooling neck and distance piece
With cooling neck
Standard without cooling neck
2 × Pt100
1 Pt100 (1)
2 Pt100 (1)
3 Pt100 (2)
4 Pt100 (2)
5 N.C
To connect with M12 connector
5-pin 4-20 mA
8-pin 4-20 mA
1
+ supply, 4-20 mA
1
N.C.
2
Common for relays
2
+ supply, 4-20 mA
3
– supply, 4-20 mA
3
Relay 2
4
Relay 2
4
Relay 2
5
Relay 1
5
Relay 1
6
Relay 1
7
– supply, 4-20 mA
8
N.C.
5 ... 10 mm
5 ... 9 -
8 ... 13 -
11 ... 15 -
85 °C
80
100 °C
Ambient temperature
Pt100
(2)
Pt100
(1)