Object 6120
Slope angle X- axis (Slope lateral)
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Object 6121
Operating parameters X-axis (Slope lateral operating parameter)
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Object 6122
Preset value X-axis (Slope lateral preset value)
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Manual_GNAMG_CANopen_EN.doc
21.11.12
0
Integer 32
ReadOnly
No
Slope angle
Value range
Depending on the device type (measuring range) and parameter in 6000h
(resolution):
(+measuring range)/resolution ... to ... (-measuring range)/resolution
Example:
Measuring range = ±30°
Resolution = 0,001
Value range: +30000...-30000
0
Unsigned 8
ReadWrite
0h
Yes
Inversion:
Inversion enabled means reverse polarity of the X-axis.
Scaling:
Scaling enabled means calculation of slope of the X-axis as follows:
Slope X –axis = physically measured slope + differential offset X- axis + offset
X-axis
If scaling is disabled:
Slope X –axis = physically measured angle
Bit 0 = 1 inversion on
0 inversion off
Bit 1 = 1 scaling on
0 scaling off
0
Integer 32
ReadWrite
0h
Yes
Sets the actual slope of the X-axis to the required value
Value range depending on parameters in object 6000h
30/41