Baumer R600V.DAE0-11209335 운영 매뉴얼 - 페이지 24

{카테고리_이름} Baumer R600V.DAE0-11209335에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer R600V.DAE0-11209335 29 페이지. Off-highway ground & crop radar sensor
Baumer R600V.DAE0-11209335에 대해서도 마찬가지입니다: 매뉴얼 (4 페이지)

Baumer R600V.DAE0-11209335 운영 매뉴얼
Manual R600V.DAE0 (EN)

4 Trouble Shooting

Tab 15 Trouble Shooting Overview

Failure
No function, no LED
Function impaired, thick layer of dirt
Mechanical damage to housing
and/or lens
Unexplained targets / distance meas-
urement in near range
Unexplained targets / distance meas-
urement in far range
The LED is blinking red (50ms on /
50ms off)
The LED is blinking magenta
The LED is blinking blue for a long pe-
riod.
No communication (also magenta
blinking)

5 Accessories

The following accessories are available for this product

Tab 16 Accessories

Art. no.
Description
11213075
ZCABL-ALL.AMP0300
Page 24 of 29
Action
Check cables, connections, power supply at pins
Clean lens and remove excess water.
Replace part by qualified personnel.
Check free space (or beyond) for non-stationary objects (such as dangling wires,
tubes, water drops on surfaces.
Check for double reflections, and limit measurement range
Hardware fault. Replace part by qualified personnel
CAN bus error. Check Tab 5 for details.
Try a power cycle. If this does not fix the issue replace part by qualified personnel
Check CAN speed (e.g. 250kbit/sec), check 120Ohm termination,
Type
Connector AMPSEAL 16 with
PUR-cable
Comment
3m cable with AMPSEAL connector
and fly-leads
R600V.DAE0_manual_1.5 (EN).docm
Last Update: 07 Jan 2021