6 SDO service

6.1

General

The device supports 1 SDO server (Expedited read/write, segmented read)
6.2

Save/load parameters

The device supports saving parameters to a non-volatile memory.

Save

6.2.1
Writing "save" to 1010h-x saves the corresponding objects to the non-volatile memory. After a reset or power-on, the
parameters are loaded from the non-volatile memory.
The SDO request to 1010h-x is answered after the saving of the parameters is performed.

Load

6.2.2
Writing "load" to 1011h-x restores the corresponding objects. The parameters are restored after a reset or power-on.

Safe non-volatile operation

6.2.3
To ensure safe non-volatile operation, the user must ensure no power interruption immediately after sending of the save
command to object 1010h-x (otherwise, the factory values are restored at the next power up).