Baumer EAM580R-SY 매뉴얼 - 페이지 20

{카테고리_이름} Baumer EAM580R-SY에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer EAM580R-SY 27 페이지. Absolute encoder with sae j1939

Baumer EAM580R-SY 매뉴얼
9.5

0x2100 Baudrate

Value
Baudrate
0
10 kBit/s
1
20 kBit/s
2
50 kBit/s
3
100 kBit/s
4
125 kBit/s
5
250 kBit/s
6
500 kBit/s
7
800 kBit/s
8
1000 kBit/s
9
Autobaud
The baudrate is activated after a reset or power-on (if parameter is saved to non-volatile memory)
Example of changing baudrate to 500 kBit/s
Description
Changing baudrate to 500 kBit/s (value 6)
Successful encoder response (60h)
Send saving of all parameters
Successful encoder response (60h)
9.6

0x6001 Measuring units per revolution

The measuring units per revolution (Singleturn resolution) of the encoder can be set WITH this object (32-Bit value)
Example of setting the ST Resolution to 3600
Description
Write Measuring Units to Encoder
Successful response by encoder (60h)
Optional send saving of all parameters
Optional successful response by encoder
(60h)
Baumer_EAM580_360_EB360_SAE_J1939_MA_EN_Rev0003.0000h_Index0004.docx
05.12.2022
Identifier
DLC
18EFAC00h
8
18EFAAACh
8
18EFAC00
8
18EFAAACh
8
Reboot of Encoder and changing of CAN-Adapter baudrate
Identifier
DLC
18EFAC00h
8
18EF00ACh
8
18EFAC00h
8
18EF00ACh
8
20/27
Protocol Data Unit (PDU)
Byte 0 ... 7 [hex]
22
00
21
00
60
00
21
00
22
10
10
01
60
10
10
01
Protocol Data Unit (PDU)
Byte 0 ... 7 [hex]
22
01
60
00
60
03
60
00
22
10
10
01
60
10
10
01
06
00
00
00
00
00
00
00
73
61
76
65
00
00
00
00
00
00
0E
10
00
00
00
00
73
61
76
65
00
00
00
00
Baumer Electric AG
Frauenfeld, Switzerland