Baumer Hubner Berlin PMG 10 설치 및 운영 지침 매뉴얼 - 페이지 38
{카테고리_이름} Baumer Hubner Berlin PMG 10에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer Hubner Berlin PMG 10 48 페이지. Absolute encoder with magnetic sensing
Baumer Hubner Berlin PMG 10에 대해서도 마찬가지입니다: 설치 및 운영 지침 매뉴얼 (36 페이지)

ELECTRICAL CONNECTION / ETHERCAT
5.
ELECTRICAL CONNECTION
5.1
EtherCAT
i
Please find a detailed instruction for the EtherCAT interface and the device descripti-
on file in the manual on the CD provided with the device.
5.1.1
Features
Bus protocol
Device profile
Features
Process data
Cycle times
Synchronization
11/21
EtherCAT
CoE (CANopen over EtherCAT) DSP406
100 MBaud Ethernet
Automatic address designation
Distributed clock for precise synchronization
Optional device configuration as „Reference Clock"
Default 10 byte PDO, configurable 4 byte PDO / 2 byte PDO for
shorter cycle times
Position value, Warnings, System time
Depending on sensor type, enabled scaling functionality and
length of PDO. Minimum cycle time: 62,5 μs
0x00 Free Run, not synchronized
0x03 Distributed clocks DC, synchronized with SyNCO/SyNC1
Event