MOUNTING / HOUSING FOOT B3
4.2
Housing foot B3
4.2.1
Mounting the spring disk coupling to the device
We recommend using the Baumer Hübner spring disk coupling K 35, see
page
11, available as accessory� When other couplings are used pay attention to
manufacturer's notes�
7
M
= 1 Nm
t
4.2.2
Mounting to the drive shaft
)
Service life restrictions and angle error by runouts
High runout of the drive shaft can cause device angle error�
High runout of the drive shaft can cause vibrations, which can shorten the ser-
vice life of the device�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The device must be mounted with cable connection facing downward and not
exposed to water�
9/27
2�5 mm
MB253EN - 11173971, 19A2, Baumer_PMG10-DeviceNet_II_EN
section 4.3,