Baumer HUBNER BERLIN PROFI NET microGen HMG10P 운영 매뉴얼 - 페이지 31

{카테고리_이름} Baumer HUBNER BERLIN PROFI NET microGen HMG10P에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HUBNER BERLIN PROFI NET microGen HMG10P 44 페이지. Incremental encoder with magnetic sensing
Baumer HUBNER BERLIN PROFI NET microGen HMG10P에 대해서도 마찬가지입니다: 설치 및 작동 지침 (32 페이지), 설치 및 작동 지침 (40 페이지)

Baumer HUBNER BERLIN PROFI NET microGen HMG10P 운영 매뉴얼
Baumer Hübner
Ill. 8: Connecting the supply cable
1
3
5
Tool
20 mm
n
n
Instruction:
a) Loosen the screws at the terminal box.
b) Lift the terminal box off the encoder.
c) Loosen the cable gland at the terminal box.
d) Insert the supply cables into the cable gland, let stick out approx. 50 mm of cable.
e) Connect cable shield to cable gland and make sure it covers a large area.
f) Assign the supply cables to the terminals.
g) Attach the cable gland to the terminal box.
h) Mount the terminal box at the encoder. To do this, tighten the screws with a torque of 2-3
Nm.
V1, T1 | HMG10 & HMG10P EtherNet/IP
5
Torx / slotted screw M4x32 mm
Cable gland M20x1.5 mm for cable di-
ameter 5...13 mm
Cable shield
22 mm
4
2
Terminal box cover
4
Connection terminals (wire cross-sec-
tion ≤ 1.5 mm
Operating Manual
Electrical installation
1
2
3
2
|
6
31