6.2.3

Switching level additional output incremental (optional)

Switching level
High/Low
Transmission length
Output frequency
I
The TTL/HTL output (Vin = Vout) at the additional incremental output is galvanically isolated
and requires separate voltage supply.
Tab. 1: Switching level additional output incremental (optional)
6.2.4

Programming interface (only for programmable variant)

Encoder parameters such as additional output, switch-off and switch-on speeds can be
changed and read out via connection SA and SB. The Z-PA.SDL1 WLAN adapter can be used
for encoder access via web browser.
Also see about this
2 Z-PA.SDL.1 WLAN adapter: Programming device for HMG10P/PMG10P [} 33]
6.2.5

LED activity indicator

LED
INC1
INC2 (additional output incre-
mental
Status
Speed
Tab. 2: LED activity indicator
V1, T1 | HMG10 & HMG10P EtherNet/IP
TTL/RS422
≥ 2,5 V / ≤ 0,5 V
≤ 550 m bei 100 kHz
≤ 600 kHz
red
No function
Undervoltage
n
Overload
n
Excess temperature
n
Internal error
Speed higher than switching
speed (overspeed)
Operating Manual
Electrical installation
TTL/HTL (Vin = Vout)
≥ 2,5 V / ≤ 0,5 V (TTL)
n
≥ Ub − 3 V / ≤ 1,5 V (HTL)
n
≤ 550 m bei 100 kHz (TTL)
n
≤ 350 m bei 100 kHz (HTL)
n
≤ 600 kHz (TTL)
n
≤ 350 kHz (HTL)
n
green
No function
OK
OK
Speed below switching speed
|
6
I
29