Safety and operating instructions
Intended use
The inclination sensor is a precision measuring device to determine angular positions and to supply the
downstream device with measured values in the form of electronic output signals. The inclination sensor
must not be used for any other purpose.
Make sure the appropriate safety measures are present to prevent damage to persons, the system or
operating facilities in case of sensor error or failure.
Personnel qualification
The inclination sensor must only be installed by a qualified electronics and precision mechanics.
Observe the user manual of the machine manufacturer.
Maintenance
The inclination sensor is maintenance-free and must not be opened or modified in its electronics or
mechanical design. Opening the sensor can lead to personal injury.
Disposal
The inclination sensor contains electronic components. At its disposal, local environmental guidelines
must be followed.
Installation
Avoid mechanical impacts or shocks on the housing.
Electrical commissioning
Do not perform any electrical modifications at the inclination sensor.
Do not carry out any wiring work when the inclination sensor is live.
Do not dock or undock the electrical connection while the inclination sensor is live.
Ensure that the entire equipment is installed in line with EMC requirements. Ambient conditions and
wiring affect the electromagnetic compatibility of the inclination sensor. Install sensor and supply cables
separately or far away from lines with high interference emissions (frequency converters, contactors,
etc.).
Provide separate power supply for the inclination sensor where working with consumers that have high
interference emissions.
Completely shield the inclination sensor housing and connecting cables.
Connect the sensor to protective earth (PE) using shielded cables. The braided shield must be
connected to the cable gland or connector. Ideally, aim at a bilateral connection to protective earth (PE),
the housing via the mechanical assembly and the cable shield via the downstream devices. In case of
earth loop problems, earth on one side only as a minimum requirement.
Supplementary information
This manual is intended as a supplement to already existing documentation (i.e. catalogue, product
information and mounting instruction).