Dover Liquip Swift 드라이버 매뉴얼 - 페이지 5

{카테고리_이름} Dover Liquip Swift에 대한 드라이버 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dover Liquip Swift 10 페이지. Delivery system

Dover Liquip Swift 드라이버 매뉴얼
3 Pumped Deliveries:
Bulk (Diesel) Deliveries & Hose Reel Deliveries (Diesel/Petrol)
TIP: Please note following options are available for Bulk and Hose Reel deliveries:
Manual Single-Compartment Drop (Partial): Section 3.1
Batch (Preset Partial Delivery): Section 3.2
Batch (Full-Compartment Delivery): Section 3.3
Manual Single-Compartment Pump Delivery (Partial)
Select "BULK", "DISL" or "PTRL" on the DFV-Swift (refer to Figure 1.1, page 2).
1.
Look at sightglass to see if the manifold has product in it and select "DRY" or "FULL"
2.
Hold down the "Manifold valve" button and press down the desired compartment button on the Swift- Mx
3.
Box for three (3) seconds.
Turn on the pump.
4.
Product is dispensed via bulk outlet (Bulk) or nozzle (Diesel or Petrol).
5.
Monitor delivered quantity (refer to Figure 1.2, Page 2 for delivery diagnostics).
6.
Complete the delivery by selecting one of the following options.
7.
delivery, "PIPE" OR "STOP."
a.
PIPE = End delivery and purge manifold pipework. This is used when the next delivery is a
different product type. Purging the pipework will deliver all remaining product in the pipework via
the bulk or nozzle used.
b.
STOP = End delivery and leave product in the manifold pipework. This is used when the next
delivery is the same product type.
HINT: Before product changeover occurs, e.g., switching from Diesel to Petrol, the manifold should be
empty (dry). The best time to empty the manifold is at the end of a delivery.
Use the "PURGE BULK HOSE" button at the end of the bulk delivery to assist with emptying the
hose.
Look at sightglass to see if the manifold has product in it and select "DRY" or "FULL"
8.
Close the nozzle/outlet and stop the pump.
9.
Select "PRNT" to complete delivery and print docket.
10.
TIP: Key Considerations:
The delivery will stop once the 200L remaining level is reached and you will be prompted to verify
that you are able to deliver the remaining amount.
If changing over product, use the "PIPE" option to purge the manifold pipework.
SAFETY ADVICE: DO NOT press "PURGE" with the cap on the bulk outlet, this will pressurise the
cap.
o
Confirm if the compartment has been emptied upon completion of delivery.
There are two options for ending a
P/N: DFV-SWIFT-DM, Version C