Follett Horizon Elite Chewblet HCF1410RMS 설치 지침 매뉴얼 - 페이지 9
{카테고리_이름} Follett Horizon Elite Chewblet HCF1410RMS에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett Horizon Elite Chewblet HCF1410RMS 17 페이지. Ice machine with ride technology installation instructions for ice manager diverter valve
Follett Horizon Elite Chewblet HCF1410RMS에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (16 페이지)
Connect utilities to docking assembly.
• Plug must be accessible after final installation.
5.1
Water and flush drain
➋
➏
silicone tubing
3/4" barb x 3/4" FPT
➍
3/4" MPT x 1" slip
➎
1" Stand pipe/Drain
• Rough-in ice machine potable water
supply
➊
. 3/8" push-in connection will be
made at included shut-off valve then at
back of docking station into solenoid.
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
pipe/drain
➎
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4 mm/0,3 m).
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
ICE MANAGER
CAUTION
➊
➌
Minimum 8"
radius
2 ft. x 1" OD
➋
.
➌
.
➍
.
➏
remote condensing
External connections
Chassis drain plumbing - required
• Plug must be removed from John Guest
fitting.
• Route 3/8" drain tubing through knockout
in back of docking station and insert fully
into John Guest fitting connection at the
rear of the machine chassis. Route other
end of 3/8" drain tubing to drain.
• Drain must slope 1/4" inch per foot (6 mm
per 30,4 cm).
5.2
Refrigerant
➊
• Braze supplied quick-connect lines onto
stub-ins
➊
.
5
9