- ページ 9
製氷機 Follett Horizon Elite Chewblet HCF1410RMSのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Follett Horizon Elite Chewblet HCF1410RMS 17 ページ。 Ice machine with ride technology installation instructions for ice manager diverter valve
Follett Horizon Elite Chewblet HCF1410RMS にも: 取付説明書 (16 ページ)
Connect utilities to docking assembly.
• Plug must be accessible after final installation.
5.1
Water and flush drain
➋
➏
silicone tubing
3/4" barb x 3/4" FPT
➍
3/4" MPT x 1" slip
➎
1" Stand pipe/Drain
• Rough-in ice machine potable water
supply
➊
. 3/8" push-in connection will be
made at included shut-off valve then at
back of docking station into solenoid.
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
pipe/drain
➎
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4 mm/0,3 m).
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
ICE MANAGER
CAUTION
➊
➌
Minimum 8"
radius
2 ft. x 1" OD
➋
.
➌
.
➍
.
➏
remote condensing
External connections
Chassis drain plumbing - required
• Plug must be removed from John Guest
fitting.
• Route 3/8" drain tubing through knockout
in back of docking station and insert fully
into John Guest fitting connection at the
rear of the machine chassis. Route other
end of 3/8" drain tubing to drain.
• Drain must slope 1/4" inch per foot (6 mm
per 30,4 cm).
5.2
Refrigerant
➊
• Braze supplied quick-connect lines onto
stub-ins
➊
.
5
9